Load and charging
ER074172H020A lists 5C continuous discharge, 10C pulse discharge for 10 seconds, and a 2C (20–80% SOC) continuous charge rate. Compare those separate ratings with your load and charging profile.

SEMI-SOLID-STATE / POUCH CELL
20Ah semi-solid-state pouch cell
ER074172H020A is a 20Ah semi-solid-state pouch cell with a 3.6V voltage platform, 5C continuous discharge rating and 319Wh/kg listed specific energy. Its dimensions are 7.8 × 74 × 172mm, with a listed weight of 225g.
01 / TECHNICAL OVERVIEW
Model-specific values for ER074172H020A. Review the voltage range, load rating, mechanical envelope and cycle duty together.
Listed cell weight: 225g. Confirm tab geometry, dimensional tolerances and swelling allowance for the assembly.
| Model | ER074172H020A |
|---|---|
| Cell format / technology | Pouch / semi-solid-state |
| Nominal capacity | 20 Ah |
| Voltage platform | 3.6 V |
| Voltage range | 2.6–4.2 V |
| Continuous discharge rate | 5C |
| Pulse discharge rate | 10C for 10 seconds |
| Continuous charge rate | 2C (20–80% SOC) |
| Cycle life | ≥ 1,000 cycles at 80% SOH |
| Listed specific energy | 319 Wh/kg |
| Dimensions (T × W × H) | 7.8 × 74 × 172 mm |
| Listed weight | 225 g |
| Discharge temperature | -40 to 60 °C |
Pulse discharge: 10C for 10 seconds. Assess pulse recovery, thermal management, SOC and cut-off conditions for the selected duty.
Cycle life is listed at 80% SOH. Discharge temperature applies to discharge; match charging conditions to the project specification. Voltage range is not a complete charging procedure.
Specific energy is the listed product-data value. Do not use capacity × voltage platform to replace it or infer a guaranteed energy value.
02 / ENGINEERING SELECTION
ER074172H020A lists 5C continuous discharge, 10C pulse discharge for 10 seconds, and a 2C (20–80% SOC) continuous charge rate. Compare those separate ratings with your load and charging profile.
The 7.8 × 74 × 172mm envelope and 225g listed weight are selection inputs. Review the ≥1,000-cycle value at 80% SOH against the intended cycle duty and complete battery-system design.
Use the aircraft voltage, load profile, mass budget, installation space and environment to evaluate this cell. A specific aircraft or device requires its own system-level validation.
UAV application considerations03 / TECHNICAL DOCUMENTATION
Include ER074172H020A, the intended application, destination market and the documents or test evidence needed by your engineering team.
SICA ENERGY / START A PROJECT
All products can be customized to your requirements. Discuss ER074172H020A or share your custom battery needs.
Request a Quote