Load and charging
ER104229H050B lists 8C continuous discharge, 10C pulse discharge for 90 seconds, and a 3C (20–80% SOC) continuous charge rate. Compare those separate ratings with your load and charging profile.

SEMI-SOLID-STATE / POUCH CELL
50Ah semi-solid-state pouch cell
ER104229H050B is a 50Ah semi-solid-state pouch cell with a 3.63V voltage platform, 8C continuous discharge rating and 285Wh/kg listed specific energy. Its dimensions are 11.8 × 104 × 229mm, with a listed weight of 636g.
01 / TECHNICAL OVERVIEW
Model-specific values for ER104229H050B. Review the voltage range, load rating, mechanical envelope and cycle duty together.
Listed cell weight: 636g. Confirm tab geometry, dimensional tolerances and swelling allowance for the assembly.
| Model | ER104229H050B |
|---|---|
| Cell format / technology | Pouch / semi-solid-state |
| Nominal capacity | 50 Ah |
| Voltage platform | 3.63 V |
| Voltage range | 2.6–4.2 V |
| Continuous discharge rate | 8C |
| Pulse discharge rate | 10C for 90 seconds |
| Continuous charge rate | 3C (20–80% SOC) |
| Cycle life | ≥ 1,500 cycles at 80% SOH |
| Listed specific energy | 285 Wh/kg |
| Dimensions (T × W × H) | 11.8 × 104 × 229 mm |
| Listed weight | 636 g |
| Discharge temperature | -40 to 60 °C |
Pulse discharge: 10C for 90 seconds. Assess pulse recovery, thermal management, SOC and cut-off conditions for the selected duty.
Cycle life is listed at 80% SOH. Discharge temperature applies to discharge; match charging conditions to the project specification. Voltage range is not a complete charging procedure.
Specific energy is the listed product-data value. Do not use capacity × voltage platform to replace it or infer a guaranteed energy value.
02 / ENGINEERING SELECTION
ER104229H050B lists 8C continuous discharge, 10C pulse discharge for 90 seconds, and a 3C (20–80% SOC) continuous charge rate. Compare those separate ratings with your load and charging profile.
The 11.8 × 104 × 229mm envelope and 636g listed weight are selection inputs. Review the ≥1,500-cycle value at 80% SOH against the intended cycle duty and complete battery-system design.
Use the aircraft voltage, load profile, mass budget, installation space and environment to evaluate this cell. A specific aircraft or device requires its own system-level validation.
UAV application considerations03 / TECHNICAL DOCUMENTATION
Include ER104229H050B, the intended application, destination market and the documents or test evidence needed by your engineering team.
SICA ENERGY / START A PROJECT
All products can be customized to your requirements. Discuss ER104229H050B or share your custom battery needs.
Request a Quote