SICA ENERGY / PROCUREMENT GUIDE

18650 vs. 21700 vs. 32700 Lithium-Ion Cells: Size, Capacity and Current Comparison

Compare eight SICA cylindrical cells by actual size, capacity, current and voltage limits, including separate pulse and 75°C cutoff entries.

· SICA Energy

An 18650 vs 21700 vs 32700 comparison should use the actual model dimensions and electrical limits, not the format name alone. SICA's eight cylindrical cells span different capacity, current, mass and voltage combinations. Even models in the same size family are not automatically interchangeable. P17 is a particular example: it lists 17Ah at 3.5V and 35A continuous discharge, with a separate 52.5A entry subject to a 75°C cutoff. This guide organizes the published model data for OEM buyers with known battery-space and load constraints. It does not turn cell ratings into pack performance, establish a charging procedure or guarantee an equipment runtime improvement.

How the Three Cell Formats Differ

Diameter and Height

The format names distinguish cylindrical size families, but a mechanical design needs the actual published outline. In this portfolio, the two 18650 models list 18.4 × 65.5mm and the two 21700 models list 21.4 × 70.5mm. The 32700 group lists 71.5mm height, with P10 at 32.34mm diameter and the other three at 32.4mm.

Dimension labels for INR18650-P2, INR21700-P5 and INR32700-P10; not to scale

Dimensions here are diameter × height. The size diagram labels these source values; it is not a manufacturing drawing or a tolerance specification. Review the applicable model drawing for terminals, insulation and the installed interface. Do not use the digits in a format name as the final battery-holder dimensions.

What Cell Format Does Not Tell You

A cell format does not independently define capacity, continuous current, pulse capability, chemistry details or charging limits. P2 and M2 share the same listed capacity and dimensions but have different current and mass entries. P5 and P6 share dimensions while differing in capacity and continuous discharge.

Three cylindrical cells labeled 18650, 21700 and 32700

For OEM cylindrical cells, select a complete model record rather than a size label. The table below preserves those distinctions and the voltage cutoffs. A larger cell can change the assembly layout and cell count; it does not by itself establish longer equipment runtime, higher usable power or a more suitable supply option.

Compare SICA's Eight Cylindrical Models

18650 and 21700 Model Comparison

The figures below are current online specification entries, not results of a new comparative test. Capacity is in Ah, current in A, dimensions in mm and mass in g. Mass is the listed maximum. The pulse duration and charge/discharge cutoffs remain visible so the table cannot be read as an unconditional current ranking.

Scroll horizontally to compare all columns, if needed. →

ModelFormatAhNominal VØ × H (mm)Max gContinuous APulse APulse timeCharge cutoff VDischarge cutoff V
INR18650-M2186502.03.718.4 × 65.5≤451050≤3s4.22.5
INR18650-P2186502.03.718.4 × 65.5≤483080≤3s4.22.5
INR21700-P5217005.03.721.4 × 70.5≤6850120≤3s4.22.5
INR21700-P6217006.03.721.4 × 70.5≤7240120≤3s4.22.5

The P5/P6 comparison is a useful reminder that higher capacity need not mean higher current capability. Follow the INR21700-P5 page for its model context; review P6 when capacity is a separate design requirement.

32700 Capacity and Voltage Differences

Scroll horizontally to compare all columns, if needed. →

ModelFormatAhNominal VØ × H (mm)Max gContinuous APulse APulse timeCharge cutoff VDischarge cutoff V
INR32700-P103270010.03.732.34 × 71.5≤14580200≤3s4.22.5
INR32700-P123270012.03.732.4 × 71.5≤15260200≤3s4.22.5
INR32700-P173270017.03.532.4 × 71.5≤16035150≤3s4.32.3
INR32700-P8327008.03.732.4 × 71.5≤14390200≤3s4.22.5

INR32700-P10 lists 10Ah and 80A continuous, while P12 lists 12Ah and 60A. P17 changes the nominal voltage and both voltage cutoffs, as well as capacity and current. It therefore requires a separate charger and system-voltage review. The 32700 lithium ion cell label does not establish a drop-in replacement among these four models.

Understand Continuous, Pulse and Thermal Limits

Published Current and Pulse Duration

The maximum pulse entries apply for ≤3 seconds in the current model summaries. They do not provide a recovery interval or a permitted repetition schedule. Continuous current and pulse current must remain separate in procurement comparisons. A short event at the listed amplitude does not establish suitability for repeated startup events or sustained work inside a pack.

Ask how the evaluation defines temperature, cooling, starting state and voltage limits. Specify your actual current/time requirement before choosing a candidate. The source cutoffs are cell-level entries, not BMS settings for a new assembly. If a condition is absent, request model-specific confirmation rather than transferring another cell's conditions.

Special 75°C Cutoff Entries

Scroll horizontally to compare all columns, if needed. →

ModelOrdinary continuous ASeparate discharge entry
INR21700-P55070 A with a 75°C cutoff
INR21700-P64050 A with a 75°C cutoff
INR32700-P1080100 A with a 75°C cutoff
INR32700-P126080 A with a 75°C cutoff
INR32700-P173552.5 A with a 75°C cutoff
INR32700-P890120 A with a 75°C cutoff

These additional values are listed with a 75°C cutoff and are not the ordinary continuous-discharge values. For P17, preserve 35A as the continuous entry and 52.5A / 75°C cutoff as a separate condition. The cutoff is not an ambient operating-temperature limit, a recommended charging temperature or proof of acceptable temperature rise in the buyer's equipment.

P2 and M2 have no corresponding additional thermal-cutoff entry in the current supplementary table. Do not fill that absence by copying a 21700 or 32700 value. This guide supplies no temperature curves or new test results.

Match a Cell to Your OEM Design

Space, Mass and Series-Parallel Design

Begin with the equipment's usable envelope, mounting arrangement and complete battery mass budget. Account for cell support, interconnections, insulation and protection separately from cell mass. A layout that fits bare cells may still fail the installed battery's structural or service requirements.

Series and parallel choices must be reviewed alongside voltage limits, load sharing and the selected cell ratings. Multiplying a single-cell current by a parallel count does not establish a validated pack rating. Compare feasible assemblies under the same equipment requirements, rather than assuming the biggest format or highest Ah value is the preferred choice.

Charging and Protection Review

Include the charger voltage/current limits, shutdown behavior and equipment input window in the selection brief. P17's 4.3V charge cutoff and 2.3V discharge cutoff differ from the 4.2V / 2.5V entries of the other seven models. Those source values need engineering review in the proposed configuration; they do not define a complete charging method by themselves.

The technology overview explains the cell-to-system distinction. SICA provides pack engineering and BMS development within an agreed scope, but a standard cell listing does not establish which protection functions will be fitted or which equipment has already been qualified.

Request Samples and Documents

Model-Specific Revision

Use the exact model identifier when discussing samples or documentation. Ask which specification revision applies, how the sample is identified and what information is available for your evaluation. A catalogue comparison is an initial reference, not a controlled drawing or an independent report.

View All Eight Cylindrical Models before selecting the records relevant to your design. Identify whether electrical limits, installation dimensions or a particular load case is driving the decision. This helps avoid requesting an interchangeable cell when the underlying voltage or mechanical requirements differ.

RFQ Inputs

To Request Model Drawings and Samples, provide candidate models, voltage window, continuous current, timed peaks, installation envelope, charger details and target market. State sample quantity, anticipated order quantity and project milestones. Drawings, available records, sample supply, MOQ and lead time are confirmed for the selected model and project.

Agree the acceptance plan before interpreting samples as an approved design. Cell qualification, pack evaluation and device validation are distinct responsibilities. This comparison does not place an order, promise delivery or imply that every model shares the same test evidence.

Continue with the relevant product and evidence.

This guide explains the inputs for a project review. It is not a customer case, performance test, certification or commitment to a particular design, quantity or delivery date.

Request Model Drawings and Samples
Chat on WhatsApp