Silver pouch battery cell with two tabs and SICA Energy branding

Review the exact model drawing for dimensions, tabs and assembly clearances.

SEMI-SOLID-STATE / POUCH CELL

104229H050A

50Ah semi-solid-state pouch cell

104229H050A is a 50Ah semi-solid-state pouch cell with a 3.6V voltage platform, 5C continuous discharge rating and 310Wh/kg listed specific energy. Its dimensions are 10.7 × 104 × 229mm, with a listed weight of 580g.

50 AhNominal capacity
5CContinuous discharge
310 Wh/kgListed specific energy
Back to pouch cells

PRODUCT OVERVIEW

Understand the model.

104229H050A is an individual 50 Ah semi-solid-state pouch cell. It lists a 3.6 V voltage platform, 5C continuous discharge and 310 Wh/kg specific energy. The voltage platform is not a complete charge/discharge profile or a measured usable-energy value.

The 50 Ah A-model lists 310 Wh/kg, 580 g, 5C continuous discharge and 10C pulses for 10 seconds. The 50 Ah B-model has an 8C continuous value and 90-second 10C pulse entry, but also different voltage, thickness, mass and cycle data.

01 / TECHNICAL OVERVIEW

Electrical &
mechanical data.

Model-specific values for 104229H050A. Review the voltage range, load rating, mechanical envelope and cycle duty together.

THICKNESS × WIDTH × HEIGHT10.7 × 104 × 229 mm

Listed cell weight: 580g. Confirm tab geometry, dimensional tolerances and swelling allowance for the assembly.

104229H050A — specifications
Model104229H050A
Cell format / technologyPouch / semi-solid-state
Nominal capacity50 Ah
Voltage platform3.6 V
Voltage range2.6–4.2 V
Continuous discharge rate5C
Pulse discharge rate10C for 10 seconds
Continuous charge rate2C (20–80% SOC)
Cycle life≥ 1,000 cycles at 80% SOH
Listed specific energy310 Wh/kg
Dimensions (T × W × H)10.7 × 104 × 229 mm
Listed weight580 g
Discharge temperature-40 to 60 °C

PERFORMANCE & TEST CONDITIONS

Read the value
with its conditions.

Published specification entries are selection inputs. Define the test method and complete operating envelope before treating them as measured performance for your equipment.

Scroll the table horizontally on small screens. Keyboard users can focus the table area.

Published entries and their interpretation
TopicPublished basisConditions to review
Discharge5C continuous; 10C pulses for 10 seconds.Compare ratings separately. Pulse recovery, SOC, cooling and cutoff conditions are not specified by the duration alone.
Charging2C (20–80% SOC) listed continuous charge rate; 2.6–4.2 V listed range.The range is not a complete charging procedure. Charging temperature, termination and any SOC-limited charging interval need separate consideration.
Cycle life≥1,000 cycles at 80% SOH.Cycling temperature, charge/discharge rates and depth of discharge are not stated in the summary. The cycle count does not establish performance under a different duty.
Temperature and specific energy-40 to 60 °C is the discharge range; 310 Wh/kg is the listed specific energy.Do not use a discharge range as a cold-charging specification. The specific-energy method is not given; capacity × voltage platform / mass does not replace the listed value.

ENGINEERING CONSIDERATIONS

Fit the battery
to the equipment.

Mechanical and tab integration

Allow for the 10.7 × 104 × 229 mm cell and 580 g listed mass. Review tab geometry, support, swelling allowance and tolerances before drawing a battery enclosure.

Energy density and discharge duty

Compare the 310 Wh/kg entry together with 5C continuous discharge, 10-second pulse duration and the charging/cycle basis. An energy-density figure does not establish peak power, system runtime or a universal model advantage.

Application evaluation

The following guides describe engineering requirements. They are not validated equipment matches, customer cases or qualification records for this model.

PRODUCT SPECIFICATION SUMMARY

104229H050A

Website summary edition 1 · Compiled 9 November 2026 from the currently listed product parameters. This is a parameter compilation for this exact model, not an independent test report, certification, performance curve or manufacturer-issued specification revision.

Nominal capacity
50 Ah
Voltage platform / range
3.6 V / 2.6–4.2 V
Continuous discharge
5C
Pulse discharge
10C for 10 s
Charge rate
2C (20–80% SOC)
Listed specific energy
310 Wh/kg
Dimensions (T × W × H)
10.7 × 104 × 229 mm
Listed mass
580 g
Cycle minimum
≥1000 cycles, 80% SOH

Use the full specifications and test-condition sections for operating limits. For procurement, request the applicable manufacturer-issued revision, dimension drawing and any model-specific records; their scope is confirmed separately.

DOCUMENTS & QUALITY

Review evidence
for the exact model.

Identify 104229H050A, the intended market and your evaluation requirements. Request the applicable specification revision, drawings and any model-specific test or transport records needed for the project. Document availability and scope are reviewed for the selected product.

Available Documentation / Request Documents

Ask about product-specific technical datasheets, UN 38.3 test documentation, SDS / MSDS and applicable transport classification records. Sea shipment documentation and air shipment documentation support are reviewed for the model, configuration, destination and shipping method. Availability and revision status are confirmed for your request.

Contact us for model-specific MOQ and lead time.

A cell-level record does not establish pack-level certification or finished-equipment compliance. Check the named product, issuer and scope of each document.

PRODUCT FAQ

Questions before procurement.

What distinguishes 104229H050A from nearby pouch cells?

The 50 Ah A-model lists 310 Wh/kg, 580 g, 5C continuous discharge and 10C pulses for 10 seconds. The 50 Ah B-model has an 8C continuous value and 90-second 10C pulse entry, but also different voltage, thickness, mass and cycle data.

Does 310 Wh/kg describe the finished battery pack?

No. It is a listed cell-level value. Pack connections, support, protection, enclosure and other components change system mass and usable energy. Compare whole-system data separately.

What does the 10-second pulse entry establish?

The listed value is 10C for 10 seconds. It does not specify pulse recovery, repeated duty or the complete thermal envelope; these need model-specific evaluation.

Is this a ready-to-install battery pack?

No. 104229H050A is a single pouch cell. Define series-parallel architecture, tab joining, mechanical support, charging and protection for the complete battery system.

SICA ENERGY / START A PROJECT

Let’s discuss your battery project.

Share your application, product model and technical requirements with SICA Energy.

Request a Quote
Chat on WhatsApp