State of charge changes how much energy a lithium-ion cell can deliver, but its role in thermal safety extends beyond a remaining-runtime percentage. The condition of the charged electrodes influences the reactions available during overheating. For an OEM buyer, that makes SOC part of the evidence specification, alongside model identity, aging state and test method.

A 2024 study by Zhu Yaning and colleagues examined 21700 NCM811 cells at five SOC levels. The results help explain why a thermal-abuse report prepared at one charge state cannot automatically represent another. This article separates the reported observations from proposed engineering review questions. The tested samples were academic research specimens, not SICA Energy products; their temperatures and timings are not SICA performance guarantees or transport permissions. The supplied visuals explain the technical setting and cell structure; they are not photographs from the cited experiments or records of SICA validation.
1. Establish What SOC Meant in This Experiment
Charge state and health state were controlled separately
The study used commercial 5.0Ah 21700 cells with an NCM811 positive electrode and graphite negative electrode. The five groups were prepared at 100%, 75%, 50%, 25% and 0% SOC, while their reported SOH remained 100%. That distinction is essential: the comparison changed charge state in fresh cells, rather than comparing fresh and aged batteries.
The normal charge and discharge endpoints were 4.2V and 2.5V for those literature samples. A 0% SOC label referred to the experiment's defined discharged state. It did not mean physically removing every source of chemical energy, nor did it imply zero terminal voltage. It must not be confused with the deliberate deep-over-discharge histories investigated in other studies.
External heating defined the challenge
Cells were externally heated at 50W in an insulated explosion-protection enclosure. The researchers recorded voltage, surface temperature and visible behavior. Temperature sampling and sensor location were part of that arrangement. These externally heated tests are not interchangeable with an accelerating rate calorimeter's sensitive heat-wait-search measurement.
For sourcing decisions, a report should state the SOC preparation method and rest conditions, not only a percentage on a cover sheet. Ask how actual capacity was established and how charge was removed or added. An SOC estimate taken from an application display is not automatically equivalent to a laboratory-prepared reference state.
2. Compare Triggering Time and Visible Outcomes
The high-SOC groups reacted sooner
Scroll horizontally to compare all columns, if needed. →
| SOC in the study | Reported runaway trigger time | Ignition observed | Flame duration |
|---|---|---|---|
| 100% | 603s | Yes | 40s |
| 75% | 836s | Yes | 31s |
| 50% | 1,169s | Yes | 23s |
| 25% | 1,472s | Yes | 11s |
| 0% | No runaway observed | No | Not applicable |
The table follows the paper's Table 4. Under this specific external-heating protocol, the charged groups triggered sooner as SOC increased. The 100% group triggered about 59.1% sooner than the 25% group. That is a relative comparison within the experiment, not a countdown available to a battery controller in service.
No observed ignition is a bounded observation
The 0% group vented but did not undergo the reported runaway event. This finding should remain tied to the tested sample and conditions. It does not establish that every discharged lithium-ion cell is harmless, that damaged cells are acceptable for shipment, or that a pack is safe after an SOC display reaches zero.
The paper also compared post-test mass loss and thermal behavior. Its SOC mass-loss figure contains a value for the 75% group that is inconsistent with the paired measurements described in the text. Rather than turn that discrepancy into an exact procurement benchmark, the useful conclusion is qualitative: the more highly charged groups generally showed more severe visible damage in this series. The timing and flame-duration table provides a clearer numerical comparison.
3. Interpret Temperature and Energy Metrics Carefully
High SOC was associated with lower characteristic temperatures for several stages and a larger temperature rise. For the 100% SOC sample, the authors reported a self-heating onset of 81.5°C, a vent-related temperature of 101.3°C, a runaway trigger of 172.5°C and a maximum surface temperature of 500.1°C. Those figures describe different physical observations, not four interchangeable safety limits.

A sensor threshold is not a material constant
The paper identified self-heating onset using a temperature-rise criterion in its external-heating arrangement. That detection rule differs from the much lower rate threshold used in the NCA calorimetry research. Directly comparing the two onset temperatures would mix chemistry, heating method and detection definition. It would not establish which commercial cell is safer.
The 0% group reached a surface maximum of 203.8°C under heating without the reported runaway event. This is another reason to preserve the event classification alongside the temperature. A high externally driven temperature does not by itself prove the same internal reaction sequence occurred.
Model-derived energy needs a narrow interpretation
The study estimated energy using cell mass, heat capacity and a temperature difference, then expressed that estimate through TNT-equivalent and damage-radius calculations. Such a simplified calculation does not capture every pathway of energy release, hot ejecta, gas combustion or enclosure pressure. It should not be presented as a measured total fire heat release or a validated separation distance.
For an OEM module, propagation risk also depends on cell spacing, heat transfer, vent direction and surrounding materials. A single-cell SOC comparison can motivate a test matrix; it cannot supply a universal module clearance or a finished enclosure rating.
4. Apply SOC Evidence to Storage and Transport Review
Operational charge policy needs a system context
An industrial system may spend most of its time at a high charge state to provide immediate backup power, or use a lower target to support a different service objective. Choosing that policy requires available energy, charging access, temperature exposure and emergency duty to be considered together. This paper does not optimize that balance for a particular product.
For evaluation, document the maximum SOC the application can reach, the normal standby state and the state at which relevant safety testing was performed. Consider whether degraded or imbalanced groups can make the displayed pack SOC a poor description of the most highly charged cell. These are engineering questions prompted by the research, rather than outcomes directly measured in the single-cell experiment.
Transport rules are separate evidence
The research does not establish a permitted shipping SOC or replace applicable transport requirements. A logistics decision depends on the goods classification, cell or pack configuration, mode of transport, destination and current rules. The absence of ignition in the 0% group is not a transport exemption.
Use model documentation to identify the evidence required for the selected goods, then consult the UN 38.3 and IEC documentation guide to distinguish test summaries, reports and shipment-specific requirements. A completed UN 38.3 record and a research thermal-abuse result answer different questions. Neither should be represented as universal approval for every configuration or shipping condition.
5. Build an OEM Qualification Brief with Clear Boundaries
Select a product, then define its evaluation state
SICA Energy's INR21700-P5 lists 5Ah and 10C (50A) continuous discharge. Those catalogue specifications do not identify it as the NCM811 sample in this paper. Similar format and capacity do not transfer the reported trigger times, peak temperature or low-SOC outcome to P5.
A useful inquiry states the application, electrical window, current profile, ambient range and expected charge policy. Add the exact cell or pack reference and identify the evidence needed at fresh and aged states. Agree whether any specialist safety testing must address the highest operating SOC and how samples will be prepared. Test scope and acceptance criteria should be settled before comparing supplier results.
When reviewing a report, check the model and revision, initial SOC and SOH, heating method, detection criterion, sensor positions, number of samples and outcome definition. Preserve unsuccessful or unexpected outcomes in the engineering review. A summary stating only that a sample passed a thermal test leaves too much of the method unspecified for a meaningful comparison.
Academic reference and evidence limits
Source: Zhu Yaning, Zhang Zhendong, Sheng Lei, Chen Long, Zhu Zehua, Fu Linxiang and Bi Qing, Experimental study on thermal runaway of 21700 Li-ion battery under different charging conditions, Journal of Automotive Safety and Energy, 2024, 15(2), 218–225. DOI: 10.3969/j.issn.1674-8484.2024.02.010. The trigger-time and flame-duration comparison is from Table 4; the temperature discussion follows the experimental results section.
This is an independent engineering interpretation of published research, not a reproduction of the paper or a SICA test certificate. The small laboratory comparison supports questions for further validation. It does not quantify a field failure probability, authorize a shipping condition or prove compatibility with an OEM system.