An industrial battery can still deliver energy after an undervoltage event while carrying damage that a simple runtime check will miss. For an OEM engineer, the important question is how that history changes subsequent voltage sag, heating and service decisions. For procurement, it is whether the qualification evidence represents the condition in which the battery will actually operate.

A 2024 paper by Wang Jinghao and colleagues studied repeated over-discharge in commercial 21700 NCA cells. Its companion master's thesis provides useful comparisons at equal cycle count and equal state of health. This article interprets those academic results for battery selection and validation. The tested cells were literature samples, not SICA Energy products. Their aging rates and thermal measurements are neither SICA specifications nor evidence of product certification. The supplied technical visuals support the discussion; they do not document the researchers' experiments or SICA testing.
1. Read the Cycling Protocol Before Comparing Results
Four discharge limits, one aging interval
The journal experiment used INR21700-50E NCA cells with 4.9Ah nominal capacity and a specified normal discharge cutoff of 2.5V. Cycling took place at 25°C, with 1C discharge and 30-minute rests between charge and discharge stages. The researchers compared the normal 2.5V group with deliberately abusive 1.5V, 1.0V and 0.5V endpoints. All groups stopped after 140 cycles, when the deepest-over-discharge group reached approximately 80% remaining capacity.
Scroll horizontally to compare all columns, if needed. →
| Literature cycling endpoint | Capacity loss after 140 cycles | Capacity retention | Comparison basis |
|---|---|---|---|
| 2.5V | 5.4% | 94.6% | Normal-cycle control |
| 1.5V | 6.5% | 93.5% | Over-discharge |
| 1.0V | 9.3% | 90.7% | Over-discharge |
| 0.5V | 20.0% | 80.0% | Deepest over-discharge |
These endpoints describe research stress conditions. They are not alternative operating limits for a production pack. In particular, the comparatively small difference between 2.5V and 1.5V after this interval does not establish that repeated operation at 1.5V is acceptable.
Capacity was measured through a common window
Every ten cycles, capacity was checked using discharge to 2.5V. That common measurement window matters: the reported retention does not simply count extra energy extracted below the normal cutoff. It describes a deterioration in subsequently available capacity. Before comparing a supplier's life graph, request the aging window, reference capacity procedure and stopping rule as separate items.
2. Connect Capacity Fade with Impedance and Lithium Inventory
A smaller fuel tank is only part of the problem
Electrochemical impedance spectroscopy and differential-voltage analysis suggested that loss of lithium inventory was the dominant aging contribution in this experiment. Negative-electrode active-material loss was secondary. The reported lithium-inventory-loss indicator increased from 3.99% in the normal-cycle group to 16.54% in the 0.5V group. These are diagnostic indicators derived from the authors' method, rather than direct measurements of a universally applicable failure fraction.
The impedance measurements also showed changes consistent with increased polarization. Measurements were made at 50% SOC after temperature conditioning, so they should not be compared directly with a supplier's resistance limit recorded at another SOC, frequency or temperature. An AC resistance value and a pulse-derived DC resistance answer different questions.
Why OEM teams should care
For a pack delivering repeated current bursts, increased polarization can bring the weakest series group to its voltage limit earlier. Reduced capacity and increased impedance can therefore reinforce each other: the affected group has less usable charge and more loaded voltage sag. A pack-level capacity result alone may conceal that distribution.
As an engineering implication, record group-level voltage during representative load events and compare dispersion over time. Keep the research mechanism distinct from a diagnosis of an individual returned pack. Identifying a particular degradation mode requires suitable measurements; an undervoltage log by itself cannot prove lithium-inventory loss or copper deposition.
3. Interpret Discharge Heating Without Losing the Test Conditions
The heating experiment evaluated the already aged samples under a common normal discharge procedure. It did not repeat the abusive cycling endpoints during calorimetry. Cells began at 30°C and discharged at 0.5C to 2.5V in an accelerating rate calorimeter operating under approximately adiabatic conditions.

Scroll horizontally to compare all columns, if needed. →
| Prior cycling condition | Peak discharge heat power | Average discharge heat power |
|---|---|---|
| New reference cell | 0.56W | 0.231W |
| 2.5V control | 0.63W | 0.259W |
| 1.5V aging | 0.67W | 0.267W |
| 1.0V aging | 0.72W | 0.272W |
| 0.5V aging | 0.75W | 0.318W |
Power, total heat and temperature are different comparisons
The 0.5V-aged sample's average heat power was about 22.8% above the normal-cycle control. However, the total heat released during a discharge did not follow a simple increasing sequence because the aged cells discharged for different durations. The measured maximum temperatures also require care: the 1.5V-aged sample reached 57.78°C, while the 1.0V-aged sample reached 57.25°C. Earlier termination can limit the final temperature even when heat generation is higher during comparable discharge stages.
The engineering lesson is to compare heating at matched discharge progress and duty, alongside peak temperature and duration. Do not multiply these low-rate cell heat figures by cell count and call the result a validated cooling requirement. A real module adds thermal interfaces, busbars, unequal current sharing and heat exchange with its surroundings.
4. Separate Equal-Cycle Aging from Equal-SOH Aging
The thesis changes the comparison question
The companion thesis reports that the 2.5V, 1.5V, 1.0V and 0.5V groups reached 80% SOH after 710, 440, 220 and 140 cycles, respectively. These results are specific to the thesis protocol. They help explain why comparing all samples after 140 cycles answers a different question from comparing all samples at 80% remaining capacity.
At equal cycle count, deeper over-discharge produced more capacity degradation and higher discharge heat power in the reported series. At equal SOH, the thesis found a different ordering of resistance and heating: groups aged at higher cutoff voltages could have greater resistance and heat generation. They had taken many more cycles to reach that capacity state, with different accumulated degradation.
Turn that distinction into a validation matrix
For an OEM qualification plan, include both a service-age comparison and an end-of-life comparison where relevant. Define the calendar or cycle exposure, usable-capacity reference and resistance procedure explicitly. Record the path used to reach the target state, rather than treating an 80% SOH label as a complete description of condition.
For purchasing decisions, ask whether replacement criteria depend on capacity, loaded voltage, resistance, temperature or a combination. Two cells that both retain 80% capacity need not share the same thermal response. Conversely, the thesis does not establish a universal life multiplier for another cell chemistry, current profile or cutoff strategy.
5. Apply the Findings to Cell Selection and Project Review
Keep catalogue specifications separate
SICA Energy lists INR21700-P5 at 5Ah with 10C (50A) continuous discharge and INR21700-P6 at 6Ah with 40A continuous discharge. These are catalogue entries for different products from the NCA research sample. Neither their shared 21700 format nor a similar capacity establishes equivalent over-discharge aging or thermal behavior.
Use the battery testing service page to frame a project discussion around the chosen model, load trace, temperature range and protection behavior. Agree the applicable sample procedure and acceptance criteria before interpreting results. A high continuous-current rating does not authorize operation below a model's discharge limit.
A useful review brief identifies the weakest-group voltage under load, standby consumption after shutdown, storage duration and response to a recorded undervoltage event. It also assigns responsibility for preventing repeated automatic restart when a depleted group temporarily recovers voltage. These are proposed review inputs, not BMS settings established by the paper.
Academic references and scope
Primary source: Wang Jinghao, Li Xichao, He Qun, Dai Zuoqiang and Zheng Lili, study of over-discharge cycling aging and discharge heat generation in 21700 NCA lithium-ion batteries, Journal of Qingdao University (Natural Science Edition), 2024, 37(3), 76–81, continued on p.99. DOI: 10.3969/j.issn.1006-1037.2024.03.12. The numeric comparisons above come from its cycling results and discharge-heating analysis.
Supplementary source: Wang Jinghao, Effects of Over-Discharge Cycling on the Electrochemical Performance and Thermal Characteristics of 21700 NCA Lithium-Ion Batteries, master's thesis, Qingdao University, 2024. English title translated for identification. Its equal-cycle and equal-SOH comparisons are discussed separately here; it is not an independent replication or a SICA test report.