Mechanical and tab integration
Allow for the 7.8 × 74 × 172 mm cell and 225 g listed mass. Review tab geometry, support, swelling allowance and tolerances before drawing a battery enclosure.

Review the exact model drawing for dimensions, tabs and assembly clearances.
SEMI-SOLID-STATE / POUCH CELL
20Ah semi-solid-state pouch cell
074172H020A is a 20Ah semi-solid-state pouch cell with a 3.6V voltage platform, 5C continuous discharge rating and 319Wh/kg listed specific energy. Its dimensions are 7.8 × 74 × 172mm, with a listed weight of 225g.
PRODUCT OVERVIEW
074172H020A is an individual 20 Ah semi-solid-state pouch cell. It lists a 3.6 V voltage platform, 5C continuous discharge and 319 Wh/kg specific energy. The voltage platform is not a complete charge/discharge profile or a measured usable-energy value.
074172H020A uses a 7.8 × 74 × 172 mm envelope and 225 g listed mass, making thickness and mass central to its comparison with 074172H028A at 10.7 × 74 × 172 mm and 313 g. Both list 5C continuous discharge and 10C pulses for 10 seconds; their listed cell specific energies are 319 and 320 Wh/kg respectively. The 20 Ah cell has a ≥1,000-cycle baseline at 80% SOH and a 2C charge entry limited to 20–80% SOC. Its thinner construction does not establish a complete pack clearance or a runtime advantage.
01 / TECHNICAL OVERVIEW
Model-specific values for 074172H020A. Review the voltage range, load rating, mechanical envelope and cycle duty together.
Listed cell weight: 225g. Confirm tab geometry, dimensional tolerances and swelling allowance for the assembly.
| Model | 074172H020A |
|---|---|
| Cell format / technology | Pouch / semi-solid-state |
| Nominal capacity | 20 Ah |
| Voltage platform | 3.6 V |
| Voltage range | 2.6–4.2 V |
| Continuous discharge rate | 5C |
| Pulse discharge rate | 10C for 10 seconds |
| Continuous charge rate | 2C (20–80% SOC) |
| Cycle life | ≥ 1,000 cycles at 80% SOH |
| Listed specific energy | 319 Wh/kg |
| Dimensions (T × W × H) | 7.8 × 74 × 172 mm |
| Listed weight | 225 g |
| Discharge temperature | -40 to 60 °C |
PERFORMANCE & TEST CONDITIONS
Published specification entries are selection inputs. Define the test method and complete operating envelope before treating them as measured performance for your equipment.
Scroll the table horizontally on small screens. Keyboard users can focus the table area.
| Topic | Published basis | Conditions to review |
|---|---|---|
| Discharge | 5C continuous; 10C pulses for 10 seconds. | Compare ratings separately. Pulse recovery, SOC, cooling and cutoff conditions are not specified by the duration alone. |
| Charging | 2C (20–80% SOC) listed continuous charge rate; 2.6–4.2 V listed range. | The range is not a complete charging procedure. Charging temperature, termination and any SOC-limited charging interval need separate consideration. |
| Cycle life | ≥1,000 cycles at 80% SOH. | Cycling temperature, charge/discharge rates and depth of discharge are not stated in the summary. The cycle count does not establish performance under a different duty. |
| Temperature and specific energy | -40 to 60 °C is the discharge range; 319 Wh/kg is the listed specific energy. | Do not use a discharge range as a cold-charging specification. The specific-energy method is not given; capacity × voltage platform / mass does not replace the listed value. |
ENGINEERING CONSIDERATIONS
Allow for the 7.8 × 74 × 172 mm cell and 225 g listed mass. Review tab geometry, support, swelling allowance and tolerances before drawing a battery enclosure.
Compare the 319 Wh/kg entry together with 5C continuous discharge, 10-second pulse duration and the charging/cycle basis. An energy-density figure does not establish peak power, system runtime or a universal model advantage.
The following guides describe engineering requirements. They are not validated equipment matches, customer cases or qualification records for this model.
DOCUMENTS & QUALITY
Identify 074172H020A, the intended market and your evaluation requirements. Request the applicable specification revision, drawings and any model-specific test or transport records needed for the project. Document availability and scope are reviewed for the selected product.
Ask about product-specific technical datasheets, UN 38.3 test documentation, SDS / MSDS and applicable transport classification records. Sea shipment documentation and air shipment documentation support are reviewed for the model, configuration, destination and shipping method. Availability and revision status are confirmed for your request.
Contact us for model-specific MOQ and lead time.
A cell-level record does not establish pack-level certification or finished-equipment compliance. Check the named product, issuer and scope of each document.
PRODUCT FAQ
The 20 Ah cell lists 7.8 × 74 × 172 mm and 225 g, versus 10.7 × 74 × 172 mm and 313 g for the 28 Ah cell. Both list 5C continuous and 10C pulses for 10 seconds. Review the thinner cell against energy needs, support, tab geometry and swelling clearance rather than treating the two as interchangeable.
Both summaries list ≥1,000 cycles at 80% SOH and a 2C charge entry limited to 20–80% SOC. Those entries do not supply the full cycle protocol. Their listed specific energies, 319 and 320 Wh/kg, do not establish equal usable energy or lifetime in a finished pack.
No. It is a listed cell-level value. Pack connections, support, protection, enclosure and other components change system mass and usable energy. Compare whole-system data separately.
The listed value is 10C for 10 seconds. It does not specify pulse recovery, repeated duty or the complete thermal envelope; these need model-specific evaluation.
No. 074172H020A is a single pouch cell. Define series-parallel architecture, tab joining, mechanical support, charging and protection for the complete battery system.
SICA ENERGY / START A PROJECT
Share your application, product model and technical requirements with SICA Energy.
Request a Quote