Mechanical and tab integration
Allow for the 8 × 74 × 172 mm cell and 239 g listed mass. Review tab geometry, support, swelling allowance and tolerances before drawing a battery enclosure.

Review the exact model drawing for dimensions, tabs and assembly clearances.
SEMI-SOLID-STATE / POUCH CELL
25Ah semi-solid-state pouch cell
074172H025B is a 25Ah semi-solid-state pouch cell with a 3.48V voltage platform, 3C continuous discharge rating and 372Wh/kg listed specific energy. Its dimensions are 8 × 74 × 172mm, with a listed weight of 239g.
PRODUCT OVERVIEW
074172H025B is an individual 25 Ah semi-solid-state pouch cell. It lists a 3.48 V voltage platform, 3C continuous discharge and 372 Wh/kg specific energy. The voltage platform is not a complete charge/discharge profile or a measured usable-energy value.
This 25 Ah cell lists 372 Wh/kg, a 3.48 V voltage platform and 3C continuous discharge. The nearby 28 Ah and 30 Ah options list 5C and a 3.6 V platform. The higher listed specific energy is not evidence of higher discharge capability.
01 / TECHNICAL OVERVIEW
Model-specific values for 074172H025B. Review the voltage range, load rating, mechanical envelope and cycle duty together.
Listed cell weight: 239g. Confirm tab geometry, dimensional tolerances and swelling allowance for the assembly.
| Model | 074172H025B |
|---|---|
| Cell format / technology | Pouch / semi-solid-state |
| Nominal capacity | 25 Ah |
| Voltage platform | 3.48 V |
| Voltage range | 2.5–4.25 V |
| Continuous discharge rate | 3C |
| Pulse discharge rate | 10C for 10 seconds |
| Continuous charge rate | 1C |
| Cycle life | ≥ 500 cycles at 80% SOH |
| Listed specific energy | 372 Wh/kg |
| Dimensions (T × W × H) | 8 × 74 × 172 mm |
| Listed weight | 239 g |
| Discharge temperature | -40 to 60 °C |
PERFORMANCE & TEST CONDITIONS
Published specification entries are selection inputs. Define the test method and complete operating envelope before treating them as measured performance for your equipment.
Scroll the table horizontally on small screens. Keyboard users can focus the table area.
| Topic | Published basis | Conditions to review |
|---|---|---|
| Discharge | 3C continuous; 10C pulses for 10 seconds. | Compare ratings separately. Pulse recovery, SOC, cooling and cutoff conditions are not specified by the duration alone. |
| Charging | 1C listed continuous charge rate; 2.5–4.25 V listed range. | The range is not a complete charging procedure. Charging temperature, termination and any SOC-limited charging interval need separate consideration. |
| Cycle life | ≥500 cycles at 80% SOH. | Cycling temperature, charge/discharge rates and depth of discharge are not stated in the summary. The cycle count does not establish performance under a different duty. |
| Temperature and specific energy | -40 to 60 °C is the discharge range; 372 Wh/kg is the listed specific energy. | Do not use a discharge range as a cold-charging specification. The specific-energy method is not given; capacity × voltage platform / mass does not replace the listed value. |
ENGINEERING CONSIDERATIONS
Allow for the 8 × 74 × 172 mm cell and 239 g listed mass. Review tab geometry, support, swelling allowance and tolerances before drawing a battery enclosure.
Compare the 372 Wh/kg entry together with 3C continuous discharge, 10-second pulse duration and the charging/cycle basis. An energy-density figure does not establish peak power, system runtime or a universal model advantage.
The following guides describe engineering requirements. They are not validated equipment matches, customer cases or qualification records for this model.
DOCUMENTS & QUALITY
Identify 074172H025B, the intended market and your evaluation requirements. Request the applicable specification revision, drawings and any model-specific test or transport records needed for the project. Document availability and scope are reviewed for the selected product.
Ask about product-specific technical datasheets, UN 38.3 test documentation, SDS / MSDS and applicable transport classification records. Sea shipment documentation and air shipment documentation support are reviewed for the model, configuration, destination and shipping method. Availability and revision status are confirmed for your request.
Contact us for model-specific MOQ and lead time.
A cell-level record does not establish pack-level certification or finished-equipment compliance. Check the named product, issuer and scope of each document.
PRODUCT FAQ
This 25 Ah cell lists 372 Wh/kg, a 3.48 V voltage platform and 3C continuous discharge. The nearby 28 Ah and 30 Ah options list 5C and a 3.6 V platform. The higher listed specific energy is not evidence of higher discharge capability.
No. It is a listed cell-level value. Pack connections, support, protection, enclosure and other components change system mass and usable energy. Compare whole-system data separately.
The listed value is 10C for 10 seconds. It does not specify pulse recovery, repeated duty or the complete thermal envelope; these need model-specific evaluation.
No. 074172H025B is a single pouch cell. Define series-parallel architecture, tab joining, mechanical support, charging and protection for the complete battery system.
SICA ENERGY / START A PROJECT
Share your application, product model and technical requirements with SICA Energy.
Request a Quote