Select a semi-solid-state pouch cell by matching its voltage window, capacity, continuous load, timed pulses and mechanical requirements to the proposed equipment. The highest listed Wh/kg value does not automatically identify the most suitable cell. In SICA's range, the 40Ah 087187H040A lists 380Wh/kg and 3C continuous discharge, while the 50Ah 104229H050B lists 285Wh/kg and 8C continuous discharge. These are cell-level specification entries with different operating considerations. Compare exact models and pulse durations before planning a pack. The thirteen-model table below supports an OEM shortlist; it does not establish pack-level energy density, a shared material formulation or validated device compatibility.
Semi-Solid-State Pouch Cell Selection Basics
What the Technology Label Means
SICA manufactures the semi-solid-state pouch cells in its product portfolio. The technology label identifies the product family, but it is not a complete chemistry specification, mechanical instruction or safety qualification. Do not assume all models share an identical formulation or that a family label guarantees a particular behavior in an assembled battery.
Use the exact model identifier to request the applicable electrical and mechanical information. The pouch-cell category is the commercial selection entry point. This guide explains how to compare the existing options; it does not create a new material claim or offer evidence of an unreported test.
Nominal Voltage and Capacity
The thirteen models span listed capacities of 20Ah to 50Ah, with voltage platforms that are not all identical. The 25Ah 074172H025B lists 3.48V, the 40Ah 087187H040A lists 3.46V, and the 50Ah 104229H050B lists 3.63V. Other models in the comparison list 3.6V. Treat these values as model-specific references rather than one uniform platform.
Check the complete voltage range and charging requirements when designing the series configuration and equipment interface. A nominal voltage or capacity alone does not define a complete charging procedure. If a required condition is absent from the summary, request it for the exact model rather than transferring a value from a neighboring entry.
Specific Energy and C-Rate Are Different
Wh/kg at Cell Level
Specific energy in Wh/kg relates energy to mass. The listed 380Wh/kg for 087187H040A is a single-cell product-data value, not the specific energy of a finished battery pack. Structure, interconnections, protection and other assembly components must be considered separately when evaluating the proposed pack.
The available summary does not establish a full specific-energy test procedure or mass basis. Retain the listed value rather than replacing it with a calculation from nominal capacity, platform voltage and mass. Such a calculation is not a measured discharge-energy result and may not reproduce the source's measurement basis. Ask for the applicable method if the project depends on a precise energy target.
Continuous and Pulse C-Rate
A continuous-discharge entry and a timed pulse entry express different limits. The pulse column must retain both its C-rate and its duration. 087187H040A lists 7C for 10 seconds; 104229H050A lists 10C for 10 seconds; 104229H050B lists 10C for 90 seconds. Those durations are part of the specification, not optional footnotes.
The source summary does not define recovery intervals, permitted repetition or the full thermal conditions behind every entry. Do not treat a pulse rating as a continuous allowance. Converting C-rate and Ah into a current calculation would still not establish a validated operating current for the assembled pack. Define the actual load and request confirmation under the proposed conditions.
Compare SICA's Pouch Cell Family
The following table reproduces the existing thirteen-model dataset. Dimensions are thickness × width × height in mm; mass is the listed cell mass in g. Specific energy is cell-level Wh/kg. Continuous C-rate and pulse C-rate/duration remain separate. The table is a specification summary, not a new test report or a ranking of overall quality.
Scroll horizontally to compare all columns, if needed. →
| Model | Ah | Platform V | Cell Wh/kg | Continuous | Pulse / duration | T × W × H (mm) | g |
|---|---|---|---|---|---|---|---|
| 074172H020A | 20 | 3.6 | 319 | 5C | 10C / 10s | 7.8 × 74 × 172 | 225 |
| 074172H025B | 25 | 3.48 | 372 | 3C | 10C / 10s | 8 × 74 × 172 | 239 |
| 074172H028A | 28 | 3.6 | 320 | 5C | 10C / 10s | 10.7 × 74 × 172 | 313 |
| 074172H030A | 30 | 3.6 | 349 | 5C | 10C / 10s | 10.6 × 74 × 172 | 301 |
| 087187H031A | 31 | 3.6 | 310 | 6C | 10C / 10s | 9.7 × 87 × 187 | 365 |
| 087187H035A | 35 | 3.6 | 309 | 6C | 10C / 10s | 11 × 87 × 187 | 408 |
| 087187H039A | 39 | 3.6 | 329 | 5C | 10C / 10s | 11 × 87 × 187 | 422 |
| 087187H039B | 39 | 3.6 | 349 | 5C | 10C / 10s | 11 × 87 × 187 | 394 |
| 088188H039A | 39 | 3.6 | 326 | 5C | 10C / 10s | 10.8 × 88 × 188 | 428 |
| 088188H039D | 39 | 3.6 | 316 | 5C | 10C / 10s | 11.1 × 88 × 188 | 438 |
| 087187H040A | 40 | 3.46 | 380 | 3C | 7C / 10s | 10.1 × 87 × 187 | 367 |
| 104229H050A | 50 | 3.6 | 310 | 5C | 10C / 10s | 10.7 × 104 × 229 | 580 |
| 104229H050B | 50 | 3.63 | 285 | 8C | 10C / 90s | 11.8 × 104 × 229 | 636 |
40Ah 087187H040A
087187H040A lists 40Ah, a 3.46V voltage platform, 380Wh/kg specific energy, 3C continuous discharge and 7C for 10 seconds as the pulse entry. Its listed dimensions are 10.1 × 87 × 187mm and its mass is 367g. This combination merits consideration when cell-level mass and energy are important, subject to the actual load and integration requirements.
The high listed specific energy does not establish that the cell can replace a higher-rate model in the same device. Review voltage limits, duty cycle, mechanical arrangement and the acceptance evidence together. No swelling allowance, pack compression specification or equipment safety result can be inferred from the energy-density figure.
50Ah 104229H050A vs. 104229H050B
104229H050A lists 50Ah, 3.6V, 310Wh/kg, 5C continuous and 10C for 10 seconds. Its dimensions are 10.7 × 104 × 229mm, with a mass of 580g. 104229H050B lists 50Ah, 3.63V, 285Wh/kg, 8C continuous and 10C for 90 seconds, at 11.8 × 104 × 229mm and 636g.
The shared 50Ah label therefore hides differences in platform voltage, mass, thickness, specific energy and load entries. The B suffix is not proof of a universal improvement over A. Choose which model to evaluate from the equipment requirements and agreed test conditions. Neither model's summary establishes an installed thermal limit or a device-level operating duration.
Pack Integration Considerations
Tabs, Swelling, Support and Temperature
Request the model drawing and identify tab geometry, polarity, joining requirements and insulation interfaces. Confirm which dimensions include tabs and which tolerances apply. The body dimensions in a product table should not be treated as a complete installation drawing.

Mechanical support and allowance for dimensional change require model-specific guidance. The current summary does not supply a universal swelling percentage, compression force or mounting gap. Do not invent these values or transfer them between cells. Review the intended enclosure, service arrangement and mechanical constraints with the engineering team before fixing the pack outline.
Temperature requirements must distinguish charging from discharging and include the load and installed cooling conditions. A listed discharge-temperature range does not establish a charging-temperature range or full-rated behavior at every temperature. Request the relevant model conditions for the proposed evaluation.
Testing and Qualification
SICA's in-house product quality validation includes cycle testing and discharge evaluation under different temperature conditions. It supports discussion of SICA products and OEM/ODM projects; it is not presented here as independent external testing. Agree the sample identity, test conditions, deliverables and acceptance criteria for the project.

Cycle figures require their associated endpoint and protocol. This comparison does not turn a catalogue entry into an operating-life guarantee. Similarly, a cell-level document does not certify the final pack or equipment. If an independent certificate or accredited report is required for a target market, identify the issuing scope and applicable model separately.
Build a Pouch Cell RFQ
Size and Electrical Requirements
Describe the device, voltage window, required capacity or energy, continuous current and each pulse with its duration and repetition. Provide the intended series/parallel concept if available, and distinguish confirmed measurements from design targets. Include installation dimensions, mass limits and the drawing revision so the discussion can address both cell and pack constraints.
For a high energy density pouch battery requirement, state whether the target applies to the individual cell or the complete pack. For a pouch cell C rate comparison, state whether the requirement is continuous, a single pulse or repeated operation. These distinctions are more useful to engineering selection than a request for the highest available number.
Document and Sample Needs
Ask for the exact model specification, drawing and applicable charging/discharging conditions. Identify any documents needed for the target market and the evaluation responsibilities. Provide sample quantity, anticipated order quantity and the project milestones. MOQ, sample supply and lead time are confirmed for the actual inquiry; no fixed commercial terms are implied by this guide.
Scroll horizontally to compare all columns, if needed. →
| RFQ item | Information to provide or request |
|---|---|
| Electrical demand | Voltage window, capacity target, continuous and timed peak loads |
| Mechanical integration | Envelope, tab/interface requirements, support and tolerance questions |
| Operating conditions | Ambient environment, charging, cooling and duty cycle |
| Evaluation evidence | Model revision, sample plan, acceptance criteria and document scope |
| Supply brief | Sample and expected order quantities, destination and milestones |
Compare 13 Pouch Cells to identify a starting model. To Request Semi-Solid-State Cell Selection Support, provide the required electrical and mechanical limits and list any missing conditions that need clarification. A shortlist is an engineering starting point; final selection depends on the model-specific evidence and the agreed equipment evaluation.